HPP-100 Hand-Held Programmer
Revision 3.3 40
Group 0 Commands G / N Key-In Data Parameters
Exit Command Mode n/a 0 SEND
Define a Time Zone G 0 1 [tz#] [start : hh mm] [stop : hh mm] [day code]
SEND
(0-5, 7), hour (00-23), day code (000-127)
Set Anti-Passback N 0 3 [1/2] SEND 1 = ON, 2 = OFF
Set Auto-Unlock Time Zones N 0 4 [tz#] [tz#] SEND (0-5, 7), (0-5, 7)
Memory Module Commands Key-In Data Parameters
Transfer Cards to Memory Module N 0 2 SEND
Transfer Events to Memory Module N 0 5 SEND
Erase Memory Module n/a 0 6 VOID SEND
Set Data File Identifier n/a 0 7 [id#] SEND (000-999)
Erase Events in Memory Module n/a 0 8 SEND
Transfer Cards from Memory Module G 0 VOID [id#] SEND (000-999)
Level Commands Key-In Data Parameters
Configure Serial Port N LVL 9 2 [#] SEND 0 = Printer, 1 = PC, 2 = Modem
Enroll Card by Number Code G LVL 9 4 [card#] SEND (0000000000-9999999999)
Reset Anti-Passback (all cards) G LVL 9 0 SEND
Set Security Fence (for Cards) N LVL 9 6 [slot#] SEND (0000-6999)
Set Daylight Savings G LVL 9 7 [#] SEND 0 = Disabled, 1 = Enabled
Display Favorite Reader List G LVL 9 1 SEND
Transfer Card from Master to FRL G LVL 9 3 [slot#] SEND (0000-6999)
Transfer Cards from Master to FRL G LVL 9 3 [low-slot#] ZIP [high-slot#] SEND (0000-6999)
Add Reader to the FRL G LVL ENRL [rdr#] SEND (1-6)
Add Readers to the FRL G LVL ENRL [rdr#] ZIP [rdr#] SEND (1-6), (1-6)
Remove Reader from the FRL G LVL VOID [rdr#] SEND (1-6)
Remove Readers from the FRL G LVL VOID [rdr#] ZIP [rdr#] SEND (1-6), (1-6)
Master Control Commands Key-In Data Parameters
Change PIN G 9 [old PIN] VOID [new PIN] ENRL [new PIN] SEND (0000-9999), (0000-9999), (0000-9999)
Clear Reader Memory N 0 999 SEND 999 SEND