NOTE: The Global Unlock feature is not Fire Marshall approved. Check your local codes
for fire safety management.
NOTE: Global Unlock takes precedence over ALL lock or unlock commands. Any
attempt to restore an Auto Unlock/Lock time schedule while the Global Unlock feature is
active will be ignored by the master controller.
Enable Global Lock
The global lock feature uses a dedicated input on the satellite board installed on the mas-
ter controller. This option will not appear if a satellite board is not installed. When the
global lock input is triggered all online and functioning doors on the PXL network are
automatically locked.
The PXL supports five different levels of Lock implementation:
l Lock Immediately locks all PXL doors (doors which have been opened with a
valid card, a time schedule, or that have been manually unlocked, will all lock).
Lock allows credentials which have valid access to still gain access and RTE is
still enabled.
l Lockout Operates the same as Lock but NO credentials are allowed access
regardless of access level or group permissions. RTE is still enabled.
l Lockout - Allow Always Schedule The same as Lockout but allowing access to
those credentials with the Always schedule assigned. RTE is still enabled.