Keri-systems Doors.NET Manual Instrukcja Użytkownika Strona 370

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 369
Doors.NET Reference Manual
- 370 -
4. Expand the controller’s inputs in the hardware tree. The input on the master con-
troller dedicated to global lock is automatically renamed as Global Lock Input.
5. The dedicated Global Lock input is a normally-open circuit that activates Global
Lock when it’s closed. It is physically located between pins 5 and 6 of TB8 (Input 4)
on the Satellite Board connected to the master controller.
6. Now if this input on the satellite board is activated, all online PXL doors will lock
and appropriate messages are posted in Live Events.